Files
Sylpheed/tools/ppc-manual/memory/lhz.md
MechaCat02 10dc260f0c chore(tools): adopt the PPC manual and a canary launcher that works anywhere
CONSOLIDATION.md Phase 6. Both lived untracked in the project root -- on one
disk, backed up by nothing.

  tools/ppc-manual/   393 files, 3.7 MB. 455 instructions, 350 family pages,
                      598 mnemonics resolvable through index.json, plus the
                      generator that produced them.
  tools/run-canary.sh the oracle launcher.

🔴 THE LAUNCHER WAS BROKEN IN TWO WAYS AND IS REWRITTEN, not copied:

  * it pointed at `xenia-rs/sylpheed.iso`, a SYMLINK. Wine cannot resolve one
    and says "path invalid", which reads as a corrupt image rather than a path
    problem -- it has cost a session before. It now points at the real file and
    warns if handed a symlink.
  * it hardcoded one machine's absolute paths, and named `xenia-rs`, which this
    consolidation retires. Now derived from the script's own location, with
    SYLPH_CANARY_BIN / SYLPH_ISO overrides and a check that each exists.

The standing constraints are in its header where someone will read them: one
emulator at a time, Canary runs MUTED, and never judge a crash or a hang from
a Bash-launched run -- a SIGKILL that looked like the binary was the editor's
process supervisor.

⚠️ The manual's GENERATOR reads the xenia-rs source tree, which is going away.
Its decoder now lives here as crates/sylpheed-ppc, so the generator must be
repointed before it is run again. Recorded in the README rather than left for
someone to discover; the manual's content is checked in and regenerates from
nothing implicitly.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-13 21:18:00 +02:00

9.9 KiB
Raw Blame History

lhz — Load Half Word and Zero

Category: Memory · Form: D · Opcode: 0xa0000000

Assembler Mnemonics

Mnemonic XML entry Flags Description
lhz lhz — Load Half Word and Zero
lhzu lhzu — Load Half Word and Zero with Update
lhzux lhzux — Load Half Word and Zero with Update Indexed
lhzx lhzx — Load Half Word and Zero Indexed

Syntax

lhz [RD], [d]([RA0])
lhzu [RD], [d]([RA])
lhzux [RD], [RA], [RB]
lhzx [RD], [RA0], [RB]

Encoding

lhz — form D

  • Opcode word: 0xa0000000
  • Primary opcode (bits 0–5): 40
  • Extended opcode: —
  • Synchronising: no
Bits Field Meaning
0–5 OPCD primary opcode
6–10 RT destination GPR (or RS when storing)
11–15 RA source GPR (0 ⇒ literal 0 for RA0 forms)
16–31 D/SI/UI 16-bit signed or unsigned immediate

lhzu — form D

  • Opcode word: 0xa4000000
  • Primary opcode (bits 0–5): 41
  • Extended opcode: —
  • Synchronising: no
Bits Field Meaning
0–5 OPCD primary opcode
6–10 RT destination GPR (or RS when storing)
11–15 RA source GPR (0 ⇒ literal 0 for RA0 forms)
16–31 D/SI/UI 16-bit signed or unsigned immediate

lhzux — form X

  • Opcode word: 0x7c00026e
  • Primary opcode (bits 0–5): 31
  • Extended opcode: 311
  • Synchronising: no
Bits Field Meaning
0–5 OPCD primary opcode
6–10 RT/FRT/VRT destination
11–15 RA/FRA/VRA source A
16–20 RB/FRB/VRB source B
21–30 XO extended opcode (10 bits)
31 Rc record-form flag

lhzx — form X

  • Opcode word: 0x7c00022e
  • Primary opcode (bits 0–5): 31
  • Extended opcode: 279
  • Synchronising: no
Bits Field Meaning
0–5 OPCD primary opcode
6–10 RT/FRT/VRT destination
11–15 RA/FRA/VRA source A
16–20 RB/FRB/VRB source B
21–30 XO extended opcode (10 bits)
31 Rc record-form flag

Operands

Field Role Description
RA0 lhz: read; lhzx: read Source GPR; when the encoded register number is 0 the operand is the literal 64-bit zero, not r0.
d lhz: read; lhzu: read 16-bit signed displacement (d) added to the base address register.
RD lhz: write; lhzu: write; lhzux: write; lhzx: write Destination GPR.
RA lhzu: read; lhzu: write; lhzux: read; lhzux: write Source GPR (r0–r31).
RB lhzux: read; lhzx: read Source GPR.

Register Effects

lhz

  • Reads (always): RA0, d
  • Reads (conditional): none
  • Writes (always): RD
  • Writes (conditional): none

lhzu

  • Reads (always): RA, d
  • Reads (conditional): none
  • Writes (always): RD, RA
  • Writes (conditional): none

lhzux

  • Reads (always): RA, RB
  • Reads (conditional): none
  • Writes (always): RD, RA
  • Writes (conditional): none

lhzx

  • Reads (always): RA0, RB
  • Reads (conditional): none
  • Writes (always): RD
  • Writes (conditional): none

Status-Register Effects

No condition-register or status-register effects.

Operation (pseudocode)

EA <- (RA|0) + EXTS(d)
RT <- ZEXT16_to_64(MEM(EA, 2))

C Translation Example

/* C translation: the xenia-rs interpreter arm below in           */
/* Implementation References is the authoritative semantic        */
/* snapshot. Translate it line-by-line:                            */
/*   - ctx.gpr[N]  -> r[N]       (or f[]/v[] for FPRs/VRs)        */
/*   - mem.read_u*/write_u* -> mem_read_u*_be / mem_write_u*_be   */
/*   - ctx.update_cr_signed(fld, v) -> update_cr_signed(fld, v)   */
/*   - ctx.xer_ca / xer_ov / xer_so -> xer.CA / xer.OV / xer.SO   */
/* The Register Effects and Status-Register Effects tables above  */
/* enumerate every side effect a faithful translation must emit.  */

Implementation References

lhz

xenia-rs interpreter body (frozen snapshot)
        PpcOpcode::lhz => {
            let ea = if instr.ra() == 0 { 0u64 } else { ctx.gpr[instr.ra()] };
            let ea = ea.wrapping_add(instr.d() as i64 as u64) as u32;
            ctx.gpr[instr.rd()] = mem.read_u16(ea) as u64;
            ctx.pc += 4;
        }

lhzu

xenia-rs interpreter body (frozen snapshot)
        PpcOpcode::lhzu => {
            let ea = ctx.gpr[instr.ra()].wrapping_add(instr.d() as i64 as u64) as u32;
            ctx.gpr[instr.rd()] = mem.read_u16(ea) as u64;
            ctx.gpr[instr.ra()] = ea as u64;
            ctx.pc += 4;
        }

lhzux

xenia-rs interpreter body (frozen snapshot)
        PpcOpcode::lhzux => {
            let ea = ctx.gpr[instr.ra()].wrapping_add(ctx.gpr[instr.rb()]) as u32;
            ctx.gpr[instr.rd()] = mem.read_u16(ea) as u64;
            ctx.gpr[instr.ra()] = ea as u64;
            ctx.pc += 4;
        }

lhzx

xenia-rs interpreter body (frozen snapshot)
        PpcOpcode::lhzx => {
            let ea = if instr.ra() == 0 { 0u64 } else { ctx.gpr[instr.ra()] };
            let ea = ea.wrapping_add(ctx.gpr[instr.rb()]) as u32;
            ctx.gpr[instr.rd()] = mem.read_u16(ea) as u64;
            ctx.pc += 4;
        }

Special Cases & Edge Conditions

  • Big-endian read, zero-extension. Reads 2 bytes big-endian, treats them as an unsigned 16-bit integer, zero-extends to 64 bits. The high 48 bits of RT become zero. Compare with lha, which sign-extends.
  • RA0 (non-update forms). RA = 0 in lhz / lhzx selects literal zero for absolute-address access. Update forms lhzu / lhzux invoke RA = 0 and RA = RT as invalid forms.
  • Update-form ordering. Xenia computes EA, performs the load, then writes RA ← EA. If RA == RT (an invalid form per IBM), the load result is overwritten by EA immediately.
  • No alignment requirement. Xenon executes unaligned half-word loads without faulting. MEM(EA, 2) reads the two consecutive bytes at EA.
  • Common as Unicode codepoint loader. Xbox 360 system strings are UTF-16; lhz is the canonical load for a single 16-bit codepoint.
  • Use lhz rather than lbz × 2 + shift. One fused instruction is faster and lets the load-store unit handle alignment.
  • Indexed variant operand order. lhzx RT, RA, RB — RA is the base (with RA0 semantics), RB is the offset.

IBM Reference