Files
Sylpheed/docs/re/structures/isl-unit-args.md
Sylpheed RE agent 58b404aef4 re: builtin80 is a command -- and finding that exposed an 11.75% bug in my tracker
Reading builtin80's body (0x82268460) to name it: it is NOT a predicate.  It
allocates a 20-byte object, stamps vtable 0x820A8CB0, magic 0xAB0311BA and the
unit's live object into it, pushes it onto a queue via the same helper push.i uses,
and returns 1 -- or 0 when the unit is absent.  A command.

That made the conditions listing impossible: it showed a six-way switch
`if builtin80(TCT206) == 0 … == 5` on a function returning 1 or 0.  Disassembling the
site shows two unconditional `jmp`s between the call and the compare, so 0x1B6C0 is
reached ONLY by a branch and its special[0] has nothing to do with builtin80.

op12 is unconditional -- the next instruction is never reached by fall-through -- and
the tracker walked through it exactly as it had walked through end_coroutine.  Last
iteration I fixed the instance and not the class, leaving 22x more bad sites in place
than the fix removed.

A/B over all 28 stages, 7563 sites, resetting at jmp as well:
  sites whose operands change              889  (11.75%)
  LHS unresolved, before -> after     34 (0.45%) -> 756 (10.00%)

So the previous commit's headline "0.0% unresolved" was a MISSING CHECK, not a strong
result: the linear walk always had some value to report, and reporting it was the bug.
10% is the honest figure and the other 90% is trustworthy for a reason.

Also corrected: isl-unit-args.md illustrated its diff with 0x1B6C0, which is one of
the bogus sites.  The UNIT_ARG result itself stands -- it came from reading
implementations, not from this listing -- but the example was picked from bad output.

Not done, and said so: recovering the 756 needs a dataflow join over each block's
actual predecessors, a CFG fixpoint rather than a linear pass.  The branch targets are
all known so the CFG is available; the analysis is not written.

calls and phase-ends regenerate byte-identical; conditions changes on 187 lines.
2026-08-27 05:53:20 +00:00

4.3 KiB
Raw Blame History

Which built-ins take a unit — read from the implementations, and the old set was short

isl.py's UNIT_ARG decides whether a built-in's slot-4 operand is printed as a unit name or as a raw number. It was built statistically, from operand ranges, and its own comment says slots were listed "only when the ratio stayed below 1.0" — i.e. only when every observed value resolved. That is conservative, and it was.

The direct method

isl-builtin-dispatch makes this a lookup: a built-in's stub tail-calls a fixed slot of the ScriptPhase vtable at 0x820A84BC, so the implementation can simply be read. Every unit-taking built-in opens the same way — this is unit_state, builtin80, builtin117 and builtin136, character for character:

lwz    r10, 324(r31)        ; the unit array
lwz    r11, 4(r30)          ; r30 = the local[] base, so this is local[4]
rlwinm r11, r11, 2, 0, 29   ; x4
lwzx   r11, r11, r10        ; -> the record
lwz    r11, 4(r11)          ; the handle
cmpli  cr6, 0, r11, 0x0     ; "is this squadron gone?"

Result: 31 → 55

built-ins whose implementation indexes [phase+324] by an argument 55
of the statistical set's 31, confirmed 31 — all of them
UNIT_ARG claims a unit, the implementation does not 0
implementation says unit, UNIT_ARG missed it 24

The 24: 21, 22, 23, 32, 42, 44, 46 (squadron_trace), 49, 50, 51, 55, 60, 61, 72 (group_ratio_pct), 80, 83, 94 (is_engaged), 101, 109 (set_unit_flags), 117, 136, 137 (wait_units_ready), 141, 142 (deploy_and_wait).

Zero false positives is worth stating on its own: the statistical method was right about everything it claimed and only too cautious about what it omitted.

⚠️ The first control I chose was worthless — recorded because it nearly passed

I first checked whether the additions' slot-4 operands resolve to a symbol-table-2 index. They did, 100.0 % — and it means nothing:

set operands resolving to a symtab-2 unit
the 31 baseline 100.0 %
the 24 additions 100.0 %
the 92 built-ins in neither set 99.3 %

Symbol table 2 is dense enough that almost any small integer lands in it, so the test does not discriminate. A control that the negative class also passes is not evidence, and this one was one careless glance from being written up as proof.

The control that does discriminate

isl-builtins.md documents that a symbol operand is a two-word pair — a tag holding the constant 1, then the index. So slot 0 should be 1 exactly when slot 4 is a unit:

set calls with slot0 == 1
the 31 baseline 100.0 % (13 677 calls)
the 24 additions 100.0 % (140 calls)
the 92 in neither set 2.5 % (2 903 calls)

A 40× separation, and the additions sit exactly on the positive class.

Effect on the artefacts

data/isl-stage02.txt and -phase-ends.txt regenerate byte-identical; -conditions.txt changes on 28 sites, every diff line pairing, all of them a raw number becoming a unit name:

- 0x01B6C0  if builtin80(1, 117) == 0   ->  + 0x01B6C0  if builtin80(TCT206) == 0

⚠️ That example was itself a bogus site — see isl-conditions. 0x1B6C0 is reached only by a branch, so attributing its comparison to builtin80 was wrong, and builtin80 is a command rather than a predicate. The UNIT_ARG result is unaffected — it was derived by reading implementations, not from this listing — but the illustration was picked from bad output.

🟡 Not settled

  • The 24 are still unnamed. Knowing an argument is a unit is not knowing what the built-in does. builtin80 (69 operands disc-wide) is tested against 0, 1, 2, 3, 4 in a switch chain, so it returns a small enumeration — but I am not naming it from that, and its body past the liveness check is unread.
  • builtin103 (0x8226BFA8) is a predicate over [phase+10152] and [phase+10156], neighbours of a value read out at +10160; it takes no unit. The fields have 9, 7 and 1 writers respectively, none of them read.
  • builtin105 (0x8226BFF0) tests a unit record's +16 against 4. What rec+16 holds is not established — isl-builtins.md only rules out its being what unit_state reads.