Files
Sylpheed/tools/re-capture
Sylpheed RE agent d1154d7ca6 re: REMAINING OB found and verified — big-endian u32 at 0xbdb59668
Ported onto the shared harness, the HUD changed from 4 to 8 and the intersection
collapsed in a single step: one u32be survivor at 0xbdb59668, with the u16be and
u8 hits at 0xbdb5966a and 0xbdb5966b being the low half and low byte of that same
word.

Verified live rather than asserted. Reading screenshot and memory together three
times, the one legible HUD frame showed 012 against mem@0xbdb59668 = 12; the
other two frames were unreadable rather than mismatched. This independently
rediscovers the address the earliest sessions found by digit-transition hunting,
by a completely different method.

It also corrects an earlier conclusion. A previous run intersected HUD readings
of 4 and then 11, got zero survivors in every encoding, and that was written up
as eliminating big-endian u32 for the whole region. This run shows u32be holds
the counter, so the refutation was wrong. The likely cause is the input:
ob_digits.png has templates for 0 1 2 4 8 only, so values containing other
digits are misread rather than rejected, and "11" was probably one of those. A
single bad reading poisons an intersection permanently, because it removes the
true address and nothing later can restore it. The lesson is that an
intersection method needs individually verifiable inputs -- the reader's
confidence scores were printed but never gated on.

One observation reopens the arrival question in a useful way: the counter
increases, 4 then 8 then 12 across about five minutes, measured in memory so not
a digit misread. A count of remaining marked targets that rises means targets
are being added during the mission. That does not contradict the deployment
finding, since the roster is fixed at load, but it does mean the game marks new
objective targets as the mission proceeds. Watching this one address across a
whole mission is now the obvious next experiment and costs almost nothing.
2026-08-25 05:40:30 +00:00
..

Runtime-capture harness (sylph-re container)

Screenshot-driven scripts for reading the running retail game's menus under Xenia Canary + lavapipe, headless. They assume the container helpers screenshot, vgamepad, pad are on $PATH and HOME=/sylph-home/re.

Script What it does
skip_intro.sh Boot → main menu, unattended. Taps A only while the intro movie is actually playing (frame-to-frame RMSE), then once at the PRESS Ⓐ BUTTON title. Static logo screens are left alone, so a stray tap can never land on NEW GAME.
wait_title.sh Older variant: wait for the title (green Ⓐ glyph at px 625,618) and tap A. Superseded by skip_intro.sh.
step.sh One Arsenal navigation step (down/up/next/prev/none) + a compact capture: weapon list stacked over the DATA SHEET.
sweep.sh Walk a whole weapon-type list, capturing only rows that show a DATA SHEET — locked rows (a "Conditions to Develop" panel) are detected by the brightness of the Range Class label box and skipped.
type.sh Change weapon-type tab N times (RB) and report the header strip.
hp.sh / cyc.sh Hangar hard-point carousel: cyc.sh steps it (d-pad down, not left/right) and captures the Name + DATA SHEET.

Input timing under lavapipe: the game polls input at its own low frame rate, so a 60 ms d-pad tap is dropped roughly half the time. 200 ms is reliable; 300 ms starts to auto-repeat (two rows per press).

Findings produced with these: docs/re/weapon-datasheet-runtime.md.

Guest-memory tools (no screenshots)

Script What it does
gmem.py Read the live guest address space out of /dev/shm/xenia_memory_* (Xenia's backing file), addressed by guest VA. find / read / words.
weapon_runtime.py Solve the Weapon/Shell struct layouts against the disc records and read the fields the disc defaults.
unit_discover.py Find which runtime class carries a set of ID strings, assuming no vtable: tallies the word at pointer_site - k across distinct IDs.
unit_runtime.py Same solver for the unit\UN_*.tbl definition objects (vtable 0x820af844). Unions several snapshots — unit definitions are per-stage.
schema_order.py Merge a sub-record's field-declaration order across all tables (topological sort); the layout check that pins fields no table ever values.
order_check.py Test offset = base + 4*index for one table's sub-record against solver output.
grab_tutorial.sh Cold-boot Canary, walk to the Nth TUTORIAL entry, wait for the stage load, snapshot guest RAM. One emulator per capture — backing out of a loaded mission wedges it.

Snapshot first — cp --sparse=always /dev/shm/xenia_memory_* snap.bin (~2 s) — and point $GMEM_FILE at the copy; the running emulator pegs every core under lavapipe.

🔴 pgrep -f / pkill -f match YOUR OWN shell

An agent driving this toolkit runs its commands through a wrapper shell whose command line contains the pattern being searched for. So

pgrep -f 'pilot\.py'        # matches the wrapper running this very command
pkill -f 'fly_session|pilot\.py'   # kills that wrapper — the script dies mid-way

This has cost four separate mistakes in one session: two scripts killed mid-execution, and twice a "is it already running?" guard that answered yes because it had found itself. The [p]ilot bracket trick does not help when the literal invocation (python3 pilot.py …) also appears on the wrapper's command line.

What works:

pgrep -x xenia_canary                       # exact NAME match, no -f
ps -eo pid,args | grep 'python3 pilot.py' | grep -v snapshot-bash
kill -9 <explicit pid>                      # look it up first, then kill by pid

The snapshot-bash filter is the reliable tell: the wrapper's command line always contains the shell-snapshot path.

🔴 The emulator does not survive the end of an agent turn

/work/.claude/settings.json defines a Stop hook that kill -9s every xenia_canary when a turn ends, printing "Stop hook killed N stale xenia process(es)".

So:

  • never launch a run intending to read it in a later turn — it will be dead;
  • an experiment has to produce its evidence within the turn that starts it;
  • prefer measurements that land in the first minutes of flight. REMAINING OB steps 4 → 8 → 12 inside the first few minutes, which is why a two-pass differential works in one turn while a 25-minute freeze watch does not.

This cost three iterations of investigating a "mysterious external SIGKILL", complete with cgroup and host memory forensics, before the hook was found. When a process dies at a session boundary, check the harness first.