feat: handle SIGTERM for graceful container stops (0.35.0)
`docker compose stop` and Kubernetes / Podman / systemd all send SIGTERM first; SIGINT is for interactive shells. Without a SIGTERM listener the container's stop-grace period elapses with the API still running, then SIGKILL skips the daemon shutdown path and leaks Chromium until the OS reaps the parent. Replace the bare `tokio::signal::ctrl_c()` with a select over ctrl_c and SignalKind::terminate() so the daemon.shutdown().await path runs in both cases. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -1,6 +1,6 @@
|
||||
[package]
|
||||
name = "mangalord"
|
||||
version = "0.34.0"
|
||||
version = "0.35.0"
|
||||
edition = "2021"
|
||||
default-run = "mangalord"
|
||||
|
||||
|
||||
@@ -17,10 +17,7 @@ async fn main() -> anyhow::Result<()> {
|
||||
tracing::info!(%addr, "mangalord listening");
|
||||
let listener = tokio::net::TcpListener::bind(addr).await?;
|
||||
axum::serve(listener, router)
|
||||
.with_graceful_shutdown(async {
|
||||
let _ = tokio::signal::ctrl_c().await;
|
||||
tracing::info!("ctrl-c received; shutting down");
|
||||
})
|
||||
.with_graceful_shutdown(shutdown_signal())
|
||||
.await?;
|
||||
|
||||
// Drain background tasks (crawler daemon) before exiting so Chromium
|
||||
@@ -30,3 +27,33 @@ async fn main() -> anyhow::Result<()> {
|
||||
}
|
||||
Ok(())
|
||||
}
|
||||
|
||||
/// Wait for either Ctrl-C (interactive shell) or SIGTERM (Docker /
|
||||
/// Kubernetes / Podman / systemd stop) and log which arrived. Without
|
||||
/// the SIGTERM branch, `docker compose stop` runs out its grace period
|
||||
/// and skips straight to SIGKILL — the daemon never gets the
|
||||
/// `daemon.shutdown().await` path, leaking Chromium.
|
||||
async fn shutdown_signal() {
|
||||
use tokio::signal::unix::{signal, SignalKind};
|
||||
let mut sigterm = match signal(SignalKind::terminate()) {
|
||||
Ok(s) => s,
|
||||
Err(e) => {
|
||||
// SignalKind::terminate() is supported on every Unix the
|
||||
// tokio runtime runs on; if registration fails we still
|
||||
// honour Ctrl-C so the process is at least
|
||||
// interactive-shutdownable.
|
||||
tracing::warn!(error = %e, "could not install SIGTERM handler; falling back to ctrl_c only");
|
||||
let _ = tokio::signal::ctrl_c().await;
|
||||
tracing::info!("ctrl-c received; shutting down");
|
||||
return;
|
||||
}
|
||||
};
|
||||
tokio::select! {
|
||||
_ = tokio::signal::ctrl_c() => {
|
||||
tracing::info!("ctrl-c received; shutting down");
|
||||
}
|
||||
_ = sigterm.recv() => {
|
||||
tracing::info!("SIGTERM received; shutting down");
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -1,6 +1,6 @@
|
||||
{
|
||||
"name": "mangalord-frontend",
|
||||
"version": "0.34.0",
|
||||
"version": "0.35.0",
|
||||
"private": true,
|
||||
"type": "module",
|
||||
"scripts": {
|
||||
|
||||
Reference in New Issue