CONSOLIDATION.md Phase 6. Both lived untracked in the project root -- on one
disk, backed up by nothing.
tools/ppc-manual/ 393 files, 3.7 MB. 455 instructions, 350 family pages,
598 mnemonics resolvable through index.json, plus the
generator that produced them.
tools/run-canary.sh the oracle launcher.
🔴 THE LAUNCHER WAS BROKEN IN TWO WAYS AND IS REWRITTEN, not copied:
* it pointed at `xenia-rs/sylpheed.iso`, a SYMLINK. Wine cannot resolve one
and says "path invalid", which reads as a corrupt image rather than a path
problem -- it has cost a session before. It now points at the real file and
warns if handed a symlink.
* it hardcoded one machine's absolute paths, and named `xenia-rs`, which this
consolidation retires. Now derived from the script's own location, with
SYLPH_CANARY_BIN / SYLPH_ISO overrides and a check that each exists.
The standing constraints are in its header where someone will read them: one
emulator at a time, Canary runs MUTED, and never judge a crash or a hang from
a Bash-launched run -- a SIGKILL that looked like the binary was the editor's
process supervisor.
⚠️ The manual's GENERATOR reads the xenia-rs source tree, which is going away.
Its decoder now lives here as crates/sylpheed-ppc, so the generator must be
repointed before it is run again. Recorded in the README rather than left for
someone to discover; the manual's content is checked in and regenerates from
nothing implicitly.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
5.6 KiB
5.6 KiB
lmw — Load Multiple Word
Assembler Mnemonics
| Mnemonic | XML entry | Flags | Description |
|---|---|---|---|
lmw |
lmw |
— | Load Multiple Word |
Syntax
(no disassembly template)
Encoding
lmw — form D
- Opcode word:
0xb8000000 - Primary opcode (bits 0–5):
46 - Extended opcode: —
- Synchronising: no
| Bits | Field | Meaning |
|---|---|---|
| 0–5 | OPCD |
primary opcode |
| 6–10 | RT |
destination GPR (or RS when storing) |
| 11–15 | RA |
source GPR (0 ⇒ literal 0 for RA0 forms) |
| 16–31 | D/SI/UI |
16-bit signed or unsigned immediate |
Operands
| Field | Role | Description |
|---|
Register Effects
lmw
- Reads (always): none
- Reads (conditional): none
- Writes (always): none
- Writes (conditional): none
Status-Register Effects
No condition-register or status-register effects.
Operation (pseudocode)
; Pseudocode derives directly from the xenia-rs interpreter
; arm (see Implementation References). Operation semantics:
; - Read source operands from the fields listed under Operands.
; - Apply the arithmetic / logical / memory action described
; in the Description field above.
; - Write results to the destination register(s); update any
; status bits enumerated under Status-Register Effects.
; Consult the IBM AIX reference link under IBM Reference for
; canonical PPC-style pseudocode where xenia's expression is
; terse.
C Translation Example
/* C translation: the xenia-rs interpreter arm below in */
/* Implementation References is the authoritative semantic */
/* snapshot. Translate it line-by-line: */
/* - ctx.gpr[N] -> r[N] (or f[]/v[] for FPRs/VRs) */
/* - mem.read_u*/write_u* -> mem_read_u*_be / mem_write_u*_be */
/* - ctx.update_cr_signed(fld, v) -> update_cr_signed(fld, v) */
/* - ctx.xer_ca / xer_ov / xer_so -> xer.CA / xer.OV / xer.SO */
/* The Register Effects and Status-Register Effects tables above */
/* enumerate every side effect a faithful translation must emit. */
Implementation References
lmw
- xenia-canary XML:
tools/ppc-instructions.xml— search formnem="lmw" - xenia-canary emit:
src/xenia/cpu/ppc/ppc_emit_memory.cc:705 - xenia-rs opcode:
crates/xenia-cpu/src/opcode.rs:42 - xenia-rs decoder:
crates/xenia-cpu/src/decoder.rs:369 - xenia-rs interpreter:
crates/xenia-cpu/src/interpreter.rs:1720-1734
xenia-rs interpreter body (frozen snapshot)
PpcOpcode::lmw => {
// PPCBUG-125: PowerISA marks `lmw` invalid when rA is in [rT..31];
// canary skips the write to rA in that case to preserve the EA base.
let mut ea = if instr.ra() == 0 { 0u64 } else { ctx.gpr[instr.ra()] };
ea = ea.wrapping_add(instr.d() as i64 as u64);
for r in instr.rd()..32 {
if r == instr.ra() {
ea = ea.wrapping_add(4);
continue;
}
ctx.gpr[r] = mem.read_u32(ea as u32) as u64;
ea = ea.wrapping_add(4);
}
ctx.pc += 4;
}
Special Cases & Edge Conditions
- Bulk register restore. Loads
(32 - RT)consecutive 32-bit words starting atEAintoRT,RT+1, …,r31. Used by AIX/PowerPC ABI prologues/epilogues to restore non-volatile GPRs in one instruction. Modern compilers prefer multiplelwzfor scheduling;lmwsurvives in older code and hand-rolled context-switch routines. - Loop bound from encoding. Xenia's snapshot iterates
for r in instr.rd()..32, exactly matching IBM's "load until r31 inclusive" semantic. WithRT = 28, four registers (r28..r31) are loaded. - Each word is zero-extended. Like
lwz, every loaded 32-bit word zero-extends into the destination's 64-bit GPR. The high 32 bits of eachr[k]become zero. - Big-endian read. Word at
EAgoes tor[RT], word atEA+4goes tor[RT+1], etc. Each word is itself loaded most-significant-byte-first. RA0semantics. WhenRA = 0, base is literal zero. Useful for absolute-address restoration.- Invalid forms. AIX docs declare it invalid for
RAto be in the destination range[RT, 31]— a load could overwrite the base register mid-sequence. Xenia performs loads in order without this check. - Alignment. PowerISA requires word-aligned
EA; an unalignedlmwmay raise an alignment exception on real hardware. Xenia tolerates it. - Performance trap. On modern PowerPC implementations
lmwis microcoded — slower than the equivalent sequence oflwz. Compilers avoid it.
Related Instructions
stmw— symmetric "store multiple words" (the matching epilogue/prologue partner).lwz,lwzx— single-word loads; the modern preferred form.lswi,lswx— load string (byte-granular bulk transfer).
IBM Reference
- AIX 7.3 —
lmw(Load Multiple Word) PowerISA v2.07B Book II§ "Load and Store Multiple" for invalid-form rules.