Files
Sylpheed/tools/ppc-manual/control/mfcr.md
MechaCat02 6bdbf89ebc
All checks were successful
CI / Native — linux (pull_request) Successful in 37m56s
CI / WASM — Web (pull_request) Successful in 28m5s
CI / Formatting (pull_request) Successful in 59s
chore(tools): adopt the PPC manual and a canary launcher that works anywhere
CONSOLIDATION.md Phase 6. Both lived untracked in the project root -- on one
disk, backed up by nothing.

  tools/ppc-manual/   393 files, 3.7 MB. 455 instructions, 350 family pages,
                      598 mnemonics resolvable through index.json, plus the
                      generator that produced them.
  tools/run-canary.sh the oracle launcher.

🔴 THE LAUNCHER WAS BROKEN IN TWO WAYS AND IS REWRITTEN, not copied:

  * it pointed at `xenia-rs/sylpheed.iso`, a SYMLINK. Wine cannot resolve one
    and says "path invalid", which reads as a corrupt image rather than a path
    problem -- it has cost a session before. It now points at the real file and
    warns if handed a symlink.
  * it hardcoded one machine's absolute paths, and named `xenia-rs`, which this
    consolidation retires. Now derived from the script's own location, with
    SYLPH_CANARY_BIN / SYLPH_ISO overrides and a check that each exists.

The standing constraints are in its header where someone will read them: one
emulator at a time, Canary runs MUTED, and never judge a crash or a hang from
a Bash-launched run -- a SIGKILL that looked like the binary was the editor's
process supervisor.

⚠️ The manual's GENERATOR reads the xenia-rs source tree, which is going away.
Its decoder now lives here as crates/sylpheed-ppc, so the generator must be
repointed before it is run again. Recorded in the README rather than left for
someone to discover; the manual's content is checked in and regenerates from
nothing implicitly.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-09-13 21:18:00 +02:00

4.7 KiB
Raw Blame History

mfcr — Move from Condition Register

Category: Control / CR / SPR · Form: X · Opcode: 0x7c000026

Assembler Mnemonics

Mnemonic XML entry Flags Description
mfcr mfcr Move from Condition Register

Syntax

mfcr [RD]

Encoding

mfcr — form X

  • Opcode word: 0x7c000026
  • Primary opcode (bits 05): 31
  • Extended opcode: 19
  • Synchronising: no
Bits Field Meaning
05 OPCD primary opcode
610 RT/FRT/VRT destination
1115 RA/FRA/VRA source A
1620 RB/FRB/VRB source B
2130 XO extended opcode (10 bits)
31 Rc record-form flag

Operands

Field Role Description
CR mfcr: read Condition-register update. When Rc=1, CR field 0 (or CR6 for vector compares, CR1 for FPU) is updated from the result.
RD mfcr: write Destination GPR.

Register Effects

mfcr

  • Reads (always): CR
  • Reads (conditional): none
  • Writes (always): RD
  • Writes (conditional): none

Status-Register Effects

No condition-register or status-register effects.

Operation (pseudocode)

RT <- 0x00000000 || CR

C Translation Example

/* C translation: the xenia-rs interpreter arm below in           */
/* Implementation References is the authoritative semantic        */
/* snapshot. Translate it line-by-line:                            */
/*   - ctx.gpr[N]  -> r[N]       (or f[]/v[] for FPRs/VRs)        */
/*   - mem.read_u*/write_u* -> mem_read_u*_be / mem_write_u*_be   */
/*   - ctx.update_cr_signed(fld, v) -> update_cr_signed(fld, v)   */
/*   - ctx.xer_ca / xer_ov / xer_so -> xer.CA / xer.OV / xer.SO   */
/* The Register Effects and Status-Register Effects tables above  */
/* enumerate every side effect a faithful translation must emit.  */

Implementation References

mfcr

xenia-rs interpreter body (frozen snapshot)
        PpcOpcode::mfcr => {
            ctx.gpr[instr.rd()] = ctx.cr() as u64;
            ctx.pc += 4;
        }

Special Cases & Edge Conditions

  • Operation. Packs all 32 CR bits into the low half of RD; the upper 32 bits of RD are zeroed. CR field 0 ends up in bits 32..35 of RD (i.e. bits 0..3 of the 32-bit packed value), CR field 7 in bits 60..63 (bits 28..31).
  • No CR side effect. mfcr is a read; CR is unmodified. The XL-form's nominal Rc bit is unused on this opcode.
  • Saving CR across calls. The Xbox 360 / SysV ABI requires non-volatile CR fields (CR2..CR4) to be preserved across calls. Standard prologue: mfcr r12; stw r12, 8(r1). Epilogue restores via mtcrf.
  • Bit ordering. PowerPC numbers bits big-endian (bit 0 = MSB). The encoding into the GPR follows the same convention: CR0.LT lands in bit 32 of the doubleword (the MSB of the low word). C-side translations should mask with 0xFFFFFFFFu before consuming.
  • mfocrf variant. PowerISA defines mfocrf (one CR field), encoded as mfcr with the high bit of FXM set. xenia-rs decodes both as the same opcode and ignores the FXM hint, returning the entire CR. This is benign — the spec says implementations may treat mfocrf as mfcr.
  • Not synchronising. Reorderable.
  • xenia exact match. xenia-rs packs its eight CrField structs into a u64 via ctx.cr(), mirroring spec semantics.
  • mtcrf — inverse: write selected CR fields from a GPR.
  • mcrf, mcrxr, mcrfs — narrower CR-field moves.
  • mfspr, mtspr — generic SPR moves; CR is not an SPR (it has its own opcode).

mfcr has no simplified mnemonics. mfocrf RT, FXM is a related encoding handled by the same xenia-rs slot.