ob_by_hud.py now scans seven readings of the same bytes and keeps a separate
candidate set for each, as byte offsets: u32 big and little endian, u16 both
endiannesses at both alignments, and u8. The big-endian u32 reading had been
refuted, so widening rather than assuming is the point.
u32le is much the tightest at 154 candidates against u32be's 4452. That is a
hint about the encoding rather than a result, since a rarer bit pattern narrows
faster regardless of meaning.
The run is inconclusive. The HUD read 4 at every sample, so there was no second
value to collapse the sets against, and from t=136 the candidate counts are
byte-identical across five samples in all seven encodings, which is what a
frozen guest looks like -- nothing in 32 MB changed at all. The probe had no
stall witness, so the run cannot prove it either way. One is added now.
Worth stating plainly: this is the fourth probe written without a witness and
the third whose flat output could not be distinguished from a freeze. Each time
the fix gets applied to that one script. The durable fix is the shared probe
harness already noted in this file, and the lesson recurring four times is
itself the argument for building it.
What the hunt needs is unchanged: two HUD readings at different values in
non-stalled samples. The counter moves on kills, which lands back on the combat
limit, though the earlier 4 to 11 observation shows it does move.
The correlation route is gated on marked-fighter kills, which the pilot manages
at about two per five minutes. ob_read.py already reads the counter off the
screen, so ob_by_hud.py matches the displayed value against memory directly and
needs no kills at all: screenshot, read the digits, keep heap words equal to that
value, intersect across readings.
Four readings at value 4 narrowed 6156 candidates to 4312, the expected slow
drift. Then the HUD read 11 and the intersection collapsed to zero. A word
holding this counter must equal 4 at the first four samples and 11 at the last,
and none does, so within the entity heap read as big-endian u32 the counter does
not exist. It may be u16, u8, little-endian, or outside that region. Both
previous hunts assumed big-endian u32 there, so this eliminates the assumption
rather than merely failing to find anything.
The displayed value also went up, from 4 to 11 over about 340 seconds. A pure
countdown of remaining marked targets should not rise, and the deployment work
says phase 1 gains no new participants. Three readings are possible and none is
tested: the cell being read is not REMAINING OB, the digits are misread, or the
counter genuinely counts something that can increase. The two clean readings
scored 0.95 to 0.98 against their templates, but 4 and 11 use only digits that
are in the strip, which is exactly the selection effect that would hide a wrong
reading -- the template set covers 0 1 2 4 8 only, and most samples came back
unreadable.
Next is widening the scan to u16 and u8 and to little-endian, and beyond the
entity heap, which is a change to one function and costs no combat. Extending
ob_digits.png with the missing digits would also raise the sample yield, since
only two of eleven readings in a 480 s run were usable.