Reading builtin80's body (0x82268460) to name it: it is NOT a predicate. It
allocates a 20-byte object, stamps vtable 0x820A8CB0, magic 0xAB0311BA and the
unit's live object into it, pushes it onto a queue via the same helper push.i uses,
and returns 1 -- or 0 when the unit is absent. A command.
That made the conditions listing impossible: it showed a six-way switch
`if builtin80(TCT206) == 0 … == 5` on a function returning 1 or 0. Disassembling the
site shows two unconditional `jmp`s between the call and the compare, so 0x1B6C0 is
reached ONLY by a branch and its special[0] has nothing to do with builtin80.
op12 is unconditional -- the next instruction is never reached by fall-through -- and
the tracker walked through it exactly as it had walked through end_coroutine. Last
iteration I fixed the instance and not the class, leaving 22x more bad sites in place
than the fix removed.
A/B over all 28 stages, 7563 sites, resetting at jmp as well:
sites whose operands change 889 (11.75%)
LHS unresolved, before -> after 34 (0.45%) -> 756 (10.00%)
So the previous commit's headline "0.0% unresolved" was a MISSING CHECK, not a strong
result: the linear walk always had some value to report, and reporting it was the bug.
10% is the honest figure and the other 90% is trustworthy for a reason.
Also corrected: isl-unit-args.md illustrated its diff with 0x1B6C0, which is one of
the bogus sites. The UNIT_ARG result itself stands -- it came from reading
implementations, not from this listing -- but the example was picked from bad output.
Not done, and said so: recovering the 756 needs a dataflow join over each block's
actual predecessors, a CFG fixpoint rather than a linear pass. The branch targets are
all known so the CFG is available; the analysis is not written.
calls and phase-ends regenerate byte-identical; conditions changes on 187 lines.
isl.py's UNIT_ARG decides whether a built-in's slot-4 operand prints as a unit name
or a raw number. It was inferred statistically from operand ranges and, by its own
comment, listed a slot "only when the ratio stayed below 1.0" -- conservative.
The vtable base makes it a lookup instead: every unit-taking built-in's implementation
opens with lwz 324(phase) / lwz 4(argbase) / rlwinm 2,0,29 / lwzx / lwz 4(rec). Read
directly for all 147:
implementation indexes [phase+324] by an argument 55
of the statistical set's 31, confirmed 31 (zero false positives)
UNIT_ARG claims a unit, implementation does not 0
implementation says unit, UNIT_ARG missed it 24
The 24 include builtin80, group_ratio_pct, is_engaged, set_unit_flags,
squadron_trace, wait_units_ready and deploy_and_wait. Hand-verified by reading
builtin7, 16, 80, 105, 117 and 136.
Recorded because it nearly passed: my FIRST control -- whether the additions' operands
resolve to a symbol-table-2 index -- is worthless. The additions score 100.0%, but so
do the 31 baseline (100.0%) AND the 92 built-ins in neither set (99.3%). Symtab 2 is
dense enough that almost any small integer lands in it. A control the negative class
also passes is not evidence.
The control that discriminates is the tag word: a symbol operand is a two-word pair
whose first word is the constant 1, so slot0 == 1 exactly when slot 4 is a unit --
100.0% (13677 calls) / 100.0% (140) / 2.5% (2903). A 40x separation.
Artefacts: isl-stage02.txt and -phase-ends.txt regenerate byte-identical; -conditions
changes on 28 sites, every diff line pairing, each a raw number becoming a unit name.
Left unnamed on purpose: all 24. builtin80 returns a small enum (tested 0..4 in a
switch) but its body past the liveness check is unread; builtin103 is a predicate over
[phase+10152]/[phase+10156]; builtin105 tests a unit record's +16 against 4.