Read straight off the drain, immediately after the pop:
8226D7AC lwz r11, 92(r31) ; payload+24
8226D7B8 cmpli cr6, 0, r11, 0x1
8226D7C4 bc 12, lt, 0x8226D89C ; +24 == 0 -> the SPAWN path
8226D7C8 bc 4, eq, 0x8226DA44 ; +24 > 1 -> bail
; +24 == 1 -> fall through, a NON-spawn path
So the field I recorded last iteration as "kind-tag shaped, but the drain was not
shown branching on it" does branch on it, three ways.
+24 = 0, written by built-in 19: condition sub_8226DAF8, then bl 0x822737C8 --
+28 is a code offset, matching the 79/79-vs-27.8%-control measurement.
+24 = 1, written by built-in 25: condition sub_8226DC80, no spawn, and the path
resolves +28 through [phase+244] -- symbol table 1:
8226D834 lwz r10, 112(r31) ; payload+28
8226D838 lwz r11, 244(r29) ; symtab 1
8226D848 lwzx r10, r10, r11
And that resolution checks out: over all 25 call sites disc-wide, built-in 25's
local[12] resolves to a symbol-table-1 entry 25 times out of 25, and every name is a
route -- Route_ADS101_p1F, Route_ADT107_p1F, Route_TCN004_p1S, Route_ADT202A_p2S.
The 1-12 values that looked like a puzzle two iterations ago are simply small symbol
indices. This independently confirms isl.py's SYM1_SLOTS, which lists slot 12 for
built-in 25 and was derived from operand ranges alone.
So there are two kinds of trigger: built-in 19 registers one whose payload is a
HANDLER ROUTINE, built-in 25 one whose payload is a ROUTE.
All artefacts regenerate byte-identical; documentation only.
Unread: both condition testers (sub_8226DAF8, sub_8226DC80), what the kind-1 path
does with the route past sub_8217FA08 / sub_8218CC88 / sub_8225FEA0, and the drain's
second spawn site at 0x8226DA10.
185 lines
7.7 KiB
Markdown
185 lines
7.7 KiB
Markdown
# ✅ The trigger node's layout — from a matched writer/reader pair
|
||
|
||
[isl-trigger-queue](../isl-trigger-queue.md) located the *appender* (built-in 25).
|
||
The node's contents are now read, because the **reader** was found too and the two
|
||
agree field for field.
|
||
|
||
## The reader: `sub_8226E220`
|
||
|
||
`sub_8226D740` — the per-frame engine→script drain — calls it as
|
||
|
||
```
|
||
8226D758 addi r26, r29, 272 ; r29 = the phase, so r26 = the TRIGGER CONTAINER
|
||
8226D79C or r3, r26, r26
|
||
8226D7A0 bl 0x8226E220 ; (container, &out88, &out84, &out80,
|
||
; &out120, &out92, &out112)
|
||
```
|
||
|
||
and it pops one node:
|
||
|
||
```
|
||
8226E228 lwz r10, 20(r11) ; the PENDING COUNT -- return 0 if empty
|
||
8226E244 lwz r10, 16(r11) ; the list head
|
||
8226E250 stw r10, 24(r11) ; a cursor
|
||
8226E254 lwz r11, 8(r10) ; -> the node PAYLOAD
|
||
```
|
||
|
||
## ✅ The layout, confirmed from both ends
|
||
|
||
| payload | written by built-in 25 | read by `sub_8226E220` | source |
|
||
|---|---|---|---|
|
||
| **+0** | `stw r26, 0(r30)` | → out88 | `local[4]` — the unit |
|
||
| **+4** | `stw r28, 4(r30)` | → out84 | `local[12]` |
|
||
| **+8** | `stw r27, 8(r30)` | → out80 | computed |
|
||
| **+16** | `stfd f31, 16(r30)` | → out120 (a **double**) | `local[16]` |
|
||
| **+24** | `stw r25, 24(r30)` | → out92 | the constant 1 |
|
||
| **+28** | `stw r28, 28(r30)` | → out112 | `local[12]` again |
|
||
| **+32** | `stw r11, 32(r30)` | → out116 | — |
|
||
| +36 | `stw r23, 36(r30)` | *not read here* | — |
|
||
|
||
Container: **+16** head, **+20** pending count, **+24** cursor. The `+20` matches
|
||
the count `isl-builtins.md` watched live at `phase+272+20`, from a completely
|
||
different direction.
|
||
|
||
That the writer and the reader touch the same seven offsets, in the same order,
|
||
is the check — neither was derived from the other.
|
||
|
||
`payload+0` being `local[4]` also agrees with `UNIT_ARG`, which lists built-in 25
|
||
and was derived from operand ranges.
|
||
|
||
## 🔴 Two corrections, both mine
|
||
|
||
### `[node+112]` does not exist
|
||
|
||
[isl-coroutine-spawner](../isl-coroutine-spawner.md) recorded the drain's spawns
|
||
as taking their offset from `[node+112]`. **`r31 = r1 - 256`** — it is the
|
||
**stack frame**, so `+112` is an output slot, not a node field. Withdrawn.
|
||
|
||
### And the trigger does NOT carry a routine offset
|
||
|
||
The follow-up hypothesis — that `payload+28` reaches the spawner and so names the
|
||
routines nothing else starts — does not survive. `payload+28` is `local[12]`, and
|
||
across **all 25 call sites disc-wide** those values are the small integers
|
||
**1 … 12**:
|
||
|
||
| | |
|
||
|---|---|
|
||
| land on the instruction stream | **1 / 25 = 4.0 %** |
|
||
| control, random 4-aligned offsets | 16.0 % |
|
||
| are unreached run-starts | **0** |
|
||
|
||
Below chance. They are indices of some kind, not code offsets.
|
||
|
||
⚠️ My first version of this test used **n = 2** — Stage 02 only. It happened to
|
||
give the same answer, but two samples could not have supported it either way.
|
||
|
||
## ✅ One correction to the corpus, in the other direction
|
||
|
||
`isl-builtins.md` withdrew the idea that `sub_8226E458` touches the trigger
|
||
queue, reasoning: *"At `0x8226D780` the argument is `lwz r4, 324(r29)` —
|
||
`[ScriptPhase+324]`, the unit array, not the trigger container."*
|
||
|
||
The call is `sub_8226E458(r3 = r26, r4 = [phase+324])`, and **`r26` was set to
|
||
`phase + 272` twelve instructions earlier**. The withdrawal read the *second*
|
||
argument. `sub_8226D740` does operate on the trigger container; what
|
||
`sub_8226E458` does *to* it is still unread, so only the argument is corrected
|
||
here, not the conclusion.
|
||
|
||
## ✅ RESOLVED: there are TWO appenders, and only one carries a routine
|
||
|
||
The puzzle above — `payload+28` holding a 1–12 index while the drain hands it to
|
||
a spawner that wants a code offset — had a simple cause: **built-in 25 is not the
|
||
only thing that appends a trigger node.**
|
||
|
||
Searching for functions that write a **double at +16** and a **word at +28** of
|
||
the same register finds exactly two:
|
||
|
||
| builder | how |
|
||
|---|---|
|
||
| `sub_8226A0D8` — **built-in 25**, vtable slot 28 | fills the payload inline |
|
||
| `sub_8226E160` | a free-list recycling variant, called from `sub_82269ED0` |
|
||
|
||
`sub_82269ED0` is **vtable slot 68 = built-in 19**, and it calls the builder as
|
||
|
||
```
|
||
8226A034 addi r3, r28, 272 ; the trigger container
|
||
8226A040 lwz r4, 4(r30) ; local[4] -> node+0 (the unit)
|
||
8226A03C lwz r5, 12(r30) ; local[12] -> node+4
|
||
8226A038 lfd f1, 24(r30) ; local[24] -> node+16 (double)
|
||
8226A030 lwz r8, 32(r30) ; local[32] -> node+28
|
||
```
|
||
|
||
### ✅ Built-in 19's `local[32]` IS a code offset
|
||
|
||
| over all 79 call sites disc-wide | |
|
||
|---|---|
|
||
| land on the instruction stream | **79 / 79 = 100.0 %** |
|
||
| control, random 4-aligned offsets | 27.8 % |
|
||
| value range | 12 164 … 111 080, **73 distinct** |
|
||
|
||
Large, distinct, and every one resolves — against a control that resolves barely
|
||
a quarter of the time. So **built-in 19 registers a trigger whose handler is a
|
||
routine**, and the drain's `base + payload+28` spawn is exactly that handler.
|
||
|
||
Built-in 25's `payload+28` really is a small index; the two builders simply put
|
||
different things in the same slot. Observed alongside it: built-in 25 writes
|
||
**`+24 = 1`** and built-in 19 writes **`+24 = 0`**, which is the shape of a kind
|
||
tag — 🟡 but the drain was not shown branching on it, so that is an observation,
|
||
not a reading.
|
||
|
||
## ✅ `+24` IS the kind tag — a three-way dispatch in the drain
|
||
|
||
Read straight off the drain, immediately after the pop:
|
||
|
||
```
|
||
8226D7AC lwz r11, 92(r31) ; payload+24
|
||
8226D7B8 cmpli cr6, 0, r11, 0x1
|
||
8226D7C4 bc 12, lt, 0x8226D89C ; +24 == 0 -> the SPAWN path
|
||
8226D7C8 bc 4, eq, 0x8226DA44 ; +24 > 1 -> bail
|
||
; +24 == 1 -> fall through, the OTHER path
|
||
```
|
||
|
||
| `+24` | written by | path | condition test | what `+28` is |
|
||
|---|---|---|---|---|
|
||
| **0** | **built-in 19** | `0x8226D89C` → `bl 0x822737C8` | `sub_8226DAF8` | a **code offset** (79/79 vs a 27.8 % control) |
|
||
| **1** | **built-in 25** | falls through at `0x8226D7CC` — **no spawn** | `sub_8226DC80` | an index into **`[phase+244]`** |
|
||
|
||
The non-spawn path is explicit about it:
|
||
|
||
```
|
||
8226D834 lwz r10, 112(r31) ; payload+28
|
||
8226D838 lwz r11, 244(r29) ; [phase+244] = SYMBOL TABLE 1
|
||
8226D848 lwzx r10, r10, r11 ; resolve it as a symtab-1 index
|
||
```
|
||
|
||
### ✅ And built-in 25's `+28` resolves to a ROUTE
|
||
|
||
Over all 25 call sites disc-wide, `local[12]` read through symbol table 1:
|
||
|
||
**25 of 25 resolve**, and every name is a route —
|
||
`Route_ADS101_p1F`, `Route_ADT107_p1F`, `Route_TCN004_p1S`, `Route_ADT202A_p2S`, …
|
||
|
||
So the 1–12 values that looked like a puzzle are simply small symbol indices.
|
||
This also confirms `isl.py`'s `SYM1_SLOTS`, which lists slot 12 for built-in 25
|
||
and was derived from operand ranges alone — **two independent routes, same
|
||
conclusion**.
|
||
|
||
**The two built-ins register two kinds of trigger:** built-in 19 a trigger whose
|
||
payload is a *handler routine*, built-in 25 one whose payload is a *route*.
|
||
|
||
## 🟡 Not settled
|
||
|
||
* ~~What the drain actually spawns.~~ ✅ Resolved above: built-in 19's nodes carry
|
||
a real routine offset at `+28`.
|
||
* ~~Whether `+24` selects between the two node kinds~~ ✅ It does — see above.
|
||
* **The two condition testers are unread**: `sub_8226DAF8` (kind 0) and
|
||
`sub_8226DC80` (kind 1), each gating its path on a `== 1` result.
|
||
* **What the kind-1 path DOES with the route** past `sub_8217FA08` /
|
||
`sub_8218CC88` / `sub_8225FEA0` is unread.
|
||
* **The drain's second spawn site** (`0x8226DA10`) is in a later block and was
|
||
not traced.
|
||
* **This still does not explain the unreached code.** All 79 of built-in 19's
|
||
handler offsets are already reachable — **0 are unreached run-starts**.
|
||
* **`sub_8226E458`'s effect** on the container.
|
||
* **What starts the ~15 % of unreached code** — still open, and this was not it.
|