Files
Sylpheed/tools/ppc-manual/alu/xoris.md
sim f3c512f2ab docs(ppc-manual): check every xenia-rs claim against Canary's source
The hand-written parts of the manual still described how the retired
xenia-rs interpreter behaved: its snapshots, Rust casts and helpers. Each of
those 490 statements is now either restated as what Canary's emitters and
x64 backend actually do (at the pinned canary_experimental commit), or
dropped where it only made sense for xenia-rs.

Checking them turned up claims that were wrong, not just outdated:

- VSCR[SAT] is never modelled in Canary (DID_SATURATE is a stub and mfvscr
  cannot see it); the pages said saturating ops set it stickily.
- Canary does not implement lswi/lswx/stswi/stswx, dcbi, mtfsb0/mtfsb1,
  vmsum*, vmhaddshs, vupkhpx/vupklpx, and most SPRs; pages described them
  as working.
- Traps evaluate TO in Canary; stvebx/stvehx/stvewx store one element, not
  16 bytes; mtmsrd writes only EE; fres/frsqrte/vrsqrtefp precision claims
  and the stfs "rounds under RN / sets FPSCR" claim contradicted the spec.
- Reservations are a 64 KiB block bitmap plus a value compare, not
  per-address tracking.

Claims that neither Canary's source nor a public spec settles are marked
unverified (NI at boot, vmaddcfp128 operand order, estimate bit-exactness).

Generated regions are untouched; re-running the generator changes nothing.

Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
2026-09-16 21:52:38 +02:00

4.2 KiB
Raw Permalink Blame History

xoris — XOR Immediate Shifted

Category: Integer ALU · Form: D · Opcode: 0x6c000000

Assembler Mnemonics

Mnemonic XML entry Flags Description
xoris xoris — XOR Immediate Shifted

Syntax

xoris [RA], [RS], [UIMM]

Encoding

xoris — form D

  • Opcode word: 0x6c000000
  • Primary opcode (bits 0–5): 27
  • Extended opcode: —
  • Synchronising: no
Bits Field Meaning
0–5 OPCD primary opcode
6–10 RT destination GPR (or RS when storing)
11–15 RA source GPR (0 ⇒ literal 0 for RA0 forms)
16–31 D/SI/UI 16-bit signed or unsigned immediate

Operands

Field Role Description
RS xoris: read Source GPR (alias for RD in some stores).
UIMM xoris: read 16-bit unsigned immediate. Zero-extended.
RA xoris: write Source GPR (r0–r31).

Register Effects

xoris

  • Reads (always): RS, UIMM
  • Reads (conditional): none
  • Writes (always): RA
  • Writes (conditional): none

Status-Register Effects

No condition-register or status-register effects.

Operation (pseudocode)

RA <- (RS) ^ (UIMM || 0x0000)

C Translation Example

/* No hand-written C yet. Translate the Canary emitter snapshot   */
/* under Implementation References; its HIR maps directly:        */
/*   f.LoadGPR(n) / f.StoreGPR(n, v)  -> r[n] / r[n] = v          */
/*   f.LoadFPR / StoreFPR, f.LoadVR / StoreVR -> f[n], v[n]        */
/*   f.Load(ea, T), f.Store(ea, v) -> raw read / write; emitters   */
/*     wrap them in f.ByteSwap for the big-endian guest value      */
/*   f.UpdateCR(n, v)  -> CR field n from v's LOW 32 BITS vs 0     */
/*   f.LoadCA / f.StoreCA -> xer.CA;  f.StoreSAT -> vscr.SAT       */
/*   i.XO.RA, i.D.DS, ... -> the bit-fields listed under Operands  */
/* The Register Effects and Status-Register Effects tables above  */
/* enumerate every side effect a faithful translation must emit.  */

Implementation References

xoris

Canary emitter (frozen snapshot @ f21ebd49e9)
int InstrEmit_xoris(PPCHIRBuilder& f, const InstrData& i) {
  // RA <- (RS) XOR (i32.0 || UI || i16.0)
  Value* ra =
      f.Xor(f.LoadGPR(i.D.RT), f.LoadConstantUint64(XEEXTZ16(i.D.DS) << 16));
  f.StoreGPR(i.D.RA, ra);
  return 0;
}

Special Cases & Edge Conditions

  • No record form. Like all immediate logicals other than andi./andis., xoris does not update CR0.
  • Immediate is zero-extended then shifted left 16. Only bits 32–47 of RA (PowerISA bit numbering) can be flipped; the high 32 bits and low 16 bits of RA come from RS unchanged.
  • Common pattern with xori to flip arbitrary 32-bit bitmasks: xoris RA, RS, hi16; xori RA, RA, lo16.
  • 64-bit operation. Canary: f.Xor(RS, EXTZ16(UI) << 16) on the full u64.
  • No XER, no CR.
  • RA = 0 reads r0 (not literal zero).
  • Used to toggle the high half of a 32-bit word, e.g. xoris r3, r3, 0x8000 flips bit 32 (the sign bit of the low word) — a one-instruction sign-flip on a 32-bit value.
  • xori — companion (immediate not shifted).
  • xorx — register-register XOR.
  • oris, andisx — sister immediate-shifted logicals.

IBM Reference