This repository has been archived on 2026-09-16. You can view files and clone it. You cannot open issues or pull requests or push a commit.
Files
Syplheed-Reborn/tools/re-capture
Sylpheed RE agent 70b1e453a7 re: OB address is run-dependent; watcher hunts it, HUD reader gated on confidence
ob_watch.py verifies the address against a confidence-gated HUD reading before
reporting anything, and two consecutive fresh launches settle the question:
0xbdb59668 held 3165285888 against a HUD of 4 on one, and exactly 4 on the next.
The address is not stable across launches, the old note that it recurs in about
five runs of seven was right, and the gate did its job by refusing to report a
series from an address that did not describe that run. The watcher now hunts the
address on the current run when confirmation fails, using the same intersection
method, so it no longer depends on a lucky launch.

The HUD reader is also gated now. ob_read returns a best and second score per
digit and those were printed but never checked, which is how one misread
poisoned an intersection and produced a wrong refutation of big-endian u32. A
reading is accepted only if every digit scores at least 0.80 with a margin of at
least 0.05, the rule ob_read's own docstring states.

The measurement itself is a negative. With a clean witness, zero stalled samples
of fifty, OB held at 4 for 250 seconds while the pilot targeted e010 for 1964
ticks and fired on 1635 of them. Constant fire at the marked attackers and not
one decrement, so it destroyed none, which matches the roughly two marked kills
per five minutes measured earlier. The fire rate itself rose from 4.6 % of ticks
in an earlier diagnosis to 83 % here without producing more kills.

Recorded as unreproduced rather than explained away: the run that found the
address saw the counter rise 4, 8, 12 over five minutes, and that reading was
confirmed against the HUD. This run was flat over a comparable window. Both
observations are sound and they disagree, so the rise is not a stable property
of the mission's first five minutes and presumably depends on progress this run
never reached.
2026-08-25 06:02:33 +00:00
..

Runtime-capture harness (sylph-re container)

Screenshot-driven scripts for reading the running retail game's menus under Xenia Canary + lavapipe, headless. They assume the container helpers screenshot, vgamepad, pad are on $PATH and HOME=/sylph-home/re.

Script What it does
skip_intro.sh Boot → main menu, unattended. Taps A only while the intro movie is actually playing (frame-to-frame RMSE), then once at the PRESS Ⓐ BUTTON title. Static logo screens are left alone, so a stray tap can never land on NEW GAME.
wait_title.sh Older variant: wait for the title (green Ⓐ glyph at px 625,618) and tap A. Superseded by skip_intro.sh.
step.sh One Arsenal navigation step (down/up/next/prev/none) + a compact capture: weapon list stacked over the DATA SHEET.
sweep.sh Walk a whole weapon-type list, capturing only rows that show a DATA SHEET — locked rows (a "Conditions to Develop" panel) are detected by the brightness of the Range Class label box and skipped.
type.sh Change weapon-type tab N times (RB) and report the header strip.
hp.sh / cyc.sh Hangar hard-point carousel: cyc.sh steps it (d-pad down, not left/right) and captures the Name + DATA SHEET.

Input timing under lavapipe: the game polls input at its own low frame rate, so a 60 ms d-pad tap is dropped roughly half the time. 200 ms is reliable; 300 ms starts to auto-repeat (two rows per press).

Findings produced with these: docs/re/weapon-datasheet-runtime.md.

Guest-memory tools (no screenshots)

Script What it does
gmem.py Read the live guest address space out of /dev/shm/xenia_memory_* (Xenia's backing file), addressed by guest VA. find / read / words.
weapon_runtime.py Solve the Weapon/Shell struct layouts against the disc records and read the fields the disc defaults.
unit_discover.py Find which runtime class carries a set of ID strings, assuming no vtable: tallies the word at pointer_site - k across distinct IDs.
unit_runtime.py Same solver for the unit\UN_*.tbl definition objects (vtable 0x820af844). Unions several snapshots — unit definitions are per-stage.
schema_order.py Merge a sub-record's field-declaration order across all tables (topological sort); the layout check that pins fields no table ever values.
order_check.py Test offset = base + 4*index for one table's sub-record against solver output.
grab_tutorial.sh Cold-boot Canary, walk to the Nth TUTORIAL entry, wait for the stage load, snapshot guest RAM. One emulator per capture — backing out of a loaded mission wedges it.

Snapshot first — cp --sparse=always /dev/shm/xenia_memory_* snap.bin (~2 s) — and point $GMEM_FILE at the copy; the running emulator pegs every core under lavapipe.

🔴 pgrep -f / pkill -f match YOUR OWN shell

An agent driving this toolkit runs its commands through a wrapper shell whose command line contains the pattern being searched for. So

pgrep -f 'pilot\.py'        # matches the wrapper running this very command
pkill -f 'fly_session|pilot\.py'   # kills that wrapper — the script dies mid-way

This has cost four separate mistakes in one session: two scripts killed mid-execution, and twice a "is it already running?" guard that answered yes because it had found itself. The [p]ilot bracket trick does not help when the literal invocation (python3 pilot.py …) also appears on the wrapper's command line.

What works:

pgrep -x xenia_canary                       # exact NAME match, no -f
ps -eo pid,args | grep 'python3 pilot.py' | grep -v snapshot-bash
kill -9 <explicit pid>                      # look it up first, then kill by pid

The snapshot-bash filter is the reliable tell: the wrapper's command line always contains the shell-snapshot path.

🔴 The emulator does not survive the end of an agent turn

/work/.claude/settings.json defines a Stop hook that kill -9s every xenia_canary when a turn ends, printing "Stop hook killed N stale xenia process(es)".

So:

  • never launch a run intending to read it in a later turn — it will be dead;
  • an experiment has to produce its evidence within the turn that starts it;
  • prefer measurements that land in the first minutes of flight. REMAINING OB steps 4 → 8 → 12 inside the first few minutes, which is why a two-pass differential works in one turn while a 25-minute freeze watch does not.

This cost three iterations of investigating a "mysterious external SIGKILL", complete with cgroup and host memory forensics, before the hook was found. When a process dies at a session boundary, check the harness first.