This repository has been archived on 2026-09-16. You can view files and clone it. You cannot open issues or pull requests or push a commit.
Files
Syplheed-Reborn/tools/re-capture
Sylpheed RE agent aaaa08b164 docs: the UI decode's own evidence images were unreachable -- 11 links repaired
The brief's rule is to commit reference data beside the finding so the
port can be built without a disc. Nothing had ever checked that the docs'
cited artifacts actually exist. doc_link_check.py walks every markdown
file under docs/, resolves each relative link, and reports targets that
are missing -- and separately targets that resolve to a ZERO-BYTE file,
which looks fine in any listing.

  links resolving   1038 -> 1049
  missing targets     16 -> 5
  empty targets        0 -> 0

+11 resolving and -11 missing against 11 edits: the counts pair, which is
the confirmation the pass did what it claimed and touched nothing else.

Two of the sixteen were the evidence for the UI layout decode itself.
structures/ui-rat-layout.md is what the port is built on, and its two
figures -- backing "the tutorial PAUSE menu rebuilds pixel-accurately
from its sprites" and "the same method reproduces the main menu" -- were
written as captures/ui-layout/... from a file in structures/, one
directory too shallow. The headline evidence for the decode could not be
opened from its own document.

Eleven links had the wrong relative depth with the target present. Each
was rewritten only where exactly one candidate path resolved, so nothing
was guessed; the first pass left three alone because equivalent spellings
(captures/../captures/x) failed to collapse, and a second pass normalised
them.

Five remain genuinely absent and are left rather than invented: two point
at MEMORY.md outside the repo, one at a header in the separate
xenia-canary-native tree, and two name documents that were never written
(weapon-datasheet-runtime.md, canary-build-verified-env-confound.md).
None is port-relevant. A missing document is a different problem from a
bad path and is not something a link fix should paper over.
2026-08-29 02:34:16 +00:00
..

Runtime-capture harness (sylph-re container)

Screenshot-driven scripts for reading the running retail game's menus under Xenia Canary + lavapipe, headless. They assume the container helpers screenshot, vgamepad, pad are on $PATH and HOME=/sylph-home/re.

Script What it does
skip_intro.sh Boot → main menu, unattended. Taps A only while the intro movie is actually playing (frame-to-frame RMSE), then once at the PRESS Ⓐ BUTTON title. Static logo screens are left alone, so a stray tap can never land on NEW GAME.
wait_title.sh Older variant: wait for the title (green Ⓐ glyph at px 625,618) and tap A. Superseded by skip_intro.sh.
step.sh One Arsenal navigation step (down/up/next/prev/none) + a compact capture: weapon list stacked over the DATA SHEET.
sweep.sh Walk a whole weapon-type list, capturing only rows that show a DATA SHEET — locked rows (a "Conditions to Develop" panel) are detected by the brightness of the Range Class label box and skipped.
type.sh Change weapon-type tab N times (RB) and report the header strip.
hp.sh / cyc.sh Hangar hard-point carousel: cyc.sh steps it (d-pad down, not left/right) and captures the Name + DATA SHEET.

Input timing under lavapipe: the game polls input at its own low frame rate, so a 60 ms d-pad tap is dropped roughly half the time. 200 ms is reliable; 300 ms starts to auto-repeat (two rows per press).

Findings produced with these: docs/re/weapon-datasheet-runtime.md.

Guest-memory tools (no screenshots)

Script What it does
gmem.py Read the live guest address space out of /dev/shm/xenia_memory_* (Xenia's backing file), addressed by guest VA. find / read / words.
weapon_runtime.py Solve the Weapon/Shell struct layouts against the disc records and read the fields the disc defaults.
unit_discover.py Find which runtime class carries a set of ID strings, assuming no vtable: tallies the word at pointer_site - k across distinct IDs.
unit_runtime.py Same solver for the unit\UN_*.tbl definition objects (vtable 0x820af844). Unions several snapshots — unit definitions are per-stage.
schema_order.py Merge a sub-record's field-declaration order across all tables (topological sort); the layout check that pins fields no table ever values.
order_check.py Test offset = base + 4*index for one table's sub-record against solver output.
grab_tutorial.sh Cold-boot Canary, walk to the Nth TUTORIAL entry, wait for the stage load, snapshot guest RAM. One emulator per capture — backing out of a loaded mission wedges it.

Snapshot first — cp --sparse=always /dev/shm/xenia_memory_* snap.bin (~2 s) — and point $GMEM_FILE at the copy; the running emulator pegs every core under lavapipe.

🔴 pgrep -f / pkill -f match YOUR OWN shell

An agent driving this toolkit runs its commands through a wrapper shell whose command line contains the pattern being searched for. So

pgrep -f 'pilot\.py'        # matches the wrapper running this very command
pkill -f 'fly_session|pilot\.py'   # kills that wrapper — the script dies mid-way

This has cost four separate mistakes in one session: two scripts killed mid-execution, and twice a "is it already running?" guard that answered yes because it had found itself. The [p]ilot bracket trick does not help when the literal invocation (python3 pilot.py …) also appears on the wrapper's command line.

What works:

pgrep -x xenia_canary                       # exact NAME match, no -f
ps -eo pid,args | grep 'python3 pilot.py' | grep -v snapshot-bash
kill -9 <explicit pid>                      # look it up first, then kill by pid

The snapshot-bash filter is the reliable tell: the wrapper's command line always contains the shell-snapshot path.

🔴 The emulator does not survive the end of an agent turn

/work/.claude/settings.json defines a Stop hook that kill -9s every xenia_canary when a turn ends, printing "Stop hook killed N stale xenia process(es)".

So:

  • never launch a run intending to read it in a later turn — it will be dead;
  • an experiment has to produce its evidence within the turn that starts it;
  • prefer measurements that land in the first minutes of flight. REMAINING OB steps 4 → 8 → 12 inside the first few minutes, which is why a two-pass differential works in one turn while a 25-minute freeze watch does not.

This cost three iterations of investigating a "mysterious external SIGKILL", complete with cgroup and host memory forensics, before the hook was found. When a process dies at a session boundary, check the harness first.